|
FM Transmitter Measurement Report
Created: 2023-06-25 02-16-15
Measuring equipment: P75/P175/P275 |
http://pira.cz |
Station Details
Frequency |
Signal
Reception |
Station
Name |
99.00 MHz |
5/5, 80 dBuV |
FREQ 3 |
Pilot |
RDS |
Phase
Difference |
6.8 kHz |
4.1 kHz |
1 deg |
|
Frequency Deviation
Limit |
Measuring
Tolerance |
75,0 kHz |
0,0 kHz |
MIN
Hold |
Max. Samples at |
Total
Samples |
% above 75,0
kHz |
11 kHz |
72 kHz |
17100 |
0,0058 |
|
Modulation Power
Limit |
Measuring
Tolerance |
8,0 dBr |
1,0 dBr |
MIN |
AVE |
MAX |
% above
9,0 dBr |
6,7 dBr |
7,63 dBr |
8,3 dBr |
0,0 |
|
Radio Data System
PS |
PI |
PTY |
TP |
TA |
MS |
DI |
CT |
" FREQ 3 " |
F536 |
10 (Pop M) |
1 |
0 |
1 |
3 |
2:16, 25.06.2023 |
RT |
"Meteo De : de 15 a 2 " |
AF |
EON |
89.9, 99.0 MHz |
- |
|
|